Enclosed VFD Packages, Soft Starters & Motor Controls

A motor control purchase is really three decisions: how the motor starts, what box it lives in, and what protects it. This hub maps our 1,000+ control SKUs to those decisions. For the start-method decision itself, read Soft Starter vs VFD.

Variable Frequency Drives

Format Lines Where It Fits
Chassis VFDs N700E, WDN750E, Siemens G120X Inside your existing panel - you handle enclosure and wiring
WCD enclosed packages NEMA 3R / 12 / 4 / 4X stainless Wall or outdoor mount - drive, disconnect, and operators pre-wired
IPP pump panels Siemens Irrigation wells and pivots, complete protection package
Bypass panels WDFC Keep the pump running if the drive faults

Soft Starters

Chassis units across Siemens 3RW40 (standard), 3RW50 (larger frames), and 3RW52-based WSSD packages, plus enclosed packages with disconnect and bypass. Accessories and spares stocked.

Starters, Contactors & Protection

NEMA Enclosure Cheat Sheet

Rating Keeps Out Typical Install
NEMA 1 Fingers, falling dirt Clean electrical rooms
NEMA 12 Dust, drips, oil mist General plant floor
NEMA 3R Rain, sleet, snow Outdoor wall/pole mount
NEMA 4 Hose-directed water Washdown areas, pits
NEMA 4X Hose + corrosion (stainless) Food plants, coastal, chemical

Frequently Asked Questions

Should I buy a chassis drive or an enclosed package?

If you have panel space, cooling, and someone to wire disconnect and operators, a chassis drive is cheapest. If the drive mounts on a wall, outdoors, or in washdown, a pre-wired NEMA-rated package installs in hours and carries the enclosure rating as a unit.

What is a bypass panel and when do I need one?

A bypass contactor arrangement that runs the motor across the line if the VFD faults or needs service. Any pump or fan that cannot tolerate downtime - municipal water, cooling towers, critical ventilation - should carry bypass.

What size starter does a 25 HP 460V motor need?

NEMA size 2 covers 25 HP at 460V three-phase (and 15 HP at 230V). Set the overload relay to the motor's nameplate FLA - roughly 34 amps for a typical 25 HP at 460V.

Why use a pump controller instead of a plain starter?

Pump controllers add the protection pumping actually needs - phase loss, undervoltage, rapid-cycle protection, and often level or pressure logic - in one listed package. The Siemens 3RE48 line covers NEMA-rated simplex duty.

Do enclosed drives need extra cooling outdoors in Texas?

Heat is the limit: most drives derate above 40°C (104°F) ambient, which a sun-struck enclosure exceeds easily. Shade hoods, north-facing mounts, or oversized enclosures with ventilation keep summer trips away - we factor this into every outdoor quote.

Related Resources

From a contactor to a complete pump panel - one call.

Most in-stock items ship same-day; call to confirm availability and freight.

Call (888) 203-2358